s
Supplier Of Industrial and Marine Equipments
The couplers and controllers of the modular I/O System 750 receive digital and analog signals from the I/O modules and sensors and transmit them to the actuators or higher level control systems.
Using the WAGO controllers, the signals can also be (pre-)processed. The device is designed for IP20 protection class.
It is protected against finger touch and solid impurities up to 12.5mm diameter, but not against water penetration.
Unless otherwise specified, the device must not be operated in wet and dusty environments.
Solid conductor 0.08 … 2.5 mm² / 28 … 14 AWG
Fine-stranded conductor :- 0.08 … 2.5 mm² / 28 … 14 AWG
Strip length :- 8 … 9 mm / 0.31 … 0.35 inches
Operating temperature :- 0 °C ... 55 °C, -20 °C … +60 °C for components with extended temperature range
Storage temperature :- -40 … +85 °C
Relative humidity :- 5 % to 95 % without condensation
Baud rate :- 1.2 kBd … 57.6 kBd (9600 baud (default setting)
Data width :- 1 x 24-bit input/output (3-byte user data); 1 x 40-bit input/output (5-byte user data); 1 x 8-bit control/status
Number of data bits :- 7/8, adjustable
Number of stop bits :- 1/2, adjustable
Buffer :- 120-byte input / 16-byte output
Supply voltage (system) :- 5 VDC; via data contacts
Current consumption (5 V system supply) :- 55 mA
Isolation :- 500 V system/field
Mounting type :- DIN-35 rail
Operating altitude :- 0 … 2000 m / 0 … 6562 ft
Mounting position :- horizontal (standing/lying); vertical
The couplers and controllers of the modular I/O System 750 receive digital and analog signals from the I/O modules and sensors and transmit them to the actuators or higher level control systems.
Using the WAGO controllers, the signals can also be (pre-)processed. The device is designed for IP20 protection class.
It is protected against finger touch and solid impurities up to 12.5mm diameter, but not against water penetration.
Unless otherwise specified, the device must not be operated in wet and dusty environments.
Solid conductor 0.08 … 2.5 mm² / 28 … 14 AWG
Fine-stranded conductor :- 0.08 … 2.5 mm² / 28 … 14 AWG
Strip length :- 8 … 9 mm / 0.31 … 0.35 inches
Operating temperature :- 0 °C ... 55 °C, -20 °C … +60 °C for components with extended temperature range
Storage temperature :- -40 … +85 °C
Relative humidity :- 5 % to 95 % without condensation
Baud rate :- 1.2 kBd … 57.6 kBd (9600 baud (default setting)
Data width :- 1 x 24-bit input/output (3-byte user data); 1 x 40-bit input/output (5-byte user data); 1 x 8-bit control/status
Number of data bits :- 7/8, adjustable
Number of stop bits :- 1/2, adjustable
Buffer :- 120-byte input / 16-byte output
Supply voltage (system) :- 5 VDC; via data contacts
Current consumption (5 V system supply) :- 55 mA
Isolation :- 500 V system/field
Mounting type :- DIN-35 rail
Operating altitude :- 0 … 2000 m / 0 … 6562 ft
Mounting position :- horizontal (standing/lying); vertical