· The SIPROTEC 7SA6 distance protection relay is a universal relay for protection, control and automation with a 4-line displayon the basis of the SIPROTEC 4 system.
· Its high level of flexibility makes it suitable to be implemented at all voltage levels.
· High-speed tripping time
· Impedance setting range allows very small settings for the protection of very short lines
· Self-setting detection for power swing frequencies up to 7 Hz
· Current transformer saturation detector prevents non-selective tripping by distance protection in the event of CT saturation.
· Phase-segregated teleprotection for improved selectivity and availability
· Digital relay-to-relay communication by means of an integrated serial protection data interface
· Adaptive auto-reclosure (ADT)
· Non-switched distance protection with 6 measuring systems (21/21N)
· High resistance earth-fault protection for single and three-pole tripping (50N, 51N, 67N)
· Earth-fault detection in isolated and resonant-earthed networks
· Tele (pilot) protection (85)
· Fault locator (FL)
· Power-swing detection/tripping (68/68T)
· Phase overcurrent protection (50/51/67)
· Switch-onto-fault protection (50HS)
· STUB bus overcurrent protection (50STUB)
· Overvoltage/undervoltage protection (59/27)
· Over/underfrequency protection (81O/U)
· Auto-reclosure (79)
· Synchro-check (25)
· Breaker failure protection (50BF)
· Thermal overload protection (49)
· The SIPROTEC 7SA6 distance protection relay is a universal relay for protection, control and automation with a 4-line displayon the basis of the SIPROTEC 4 system.
· Its high level of flexibility makes it suitable to be implemented at all voltage levels.
· High-speed tripping time
· Impedance setting range allows very small settings for the protection of very short lines
· Self-setting detection for power swing frequencies up to 7 Hz
· Current transformer saturation detector prevents non-selective tripping by distance protection in the event of CT saturation.
· Phase-segregated teleprotection for improved selectivity and availability
· Digital relay-to-relay communication by means of an integrated serial protection data interface
· Adaptive auto-reclosure (ADT)
· Non-switched distance protection with 6 measuring systems (21/21N)
· High resistance earth-fault protection for single and three-pole tripping (50N, 51N, 67N)
· Earth-fault detection in isolated and resonant-earthed networks
· Tele (pilot) protection (85)
· Fault locator (FL)
· Power-swing detection/tripping (68/68T)
· Phase overcurrent protection (50/51/67)
· Switch-onto-fault protection (50HS)
· STUB bus overcurrent protection (50STUB)
· Overvoltage/undervoltage protection (59/27)
· Over/underfrequency protection (81O/U)
· Auto-reclosure (79)
· Synchro-check (25)
· Breaker failure protection (50BF)
· Thermal overload protection (49)