0.075% high accuracy option
0.10% reference accuracy, including linearity, hysteresis, and repeatability
Absolute and gage pressure ranges from 0–1.5 psi to 0–4,000 psi (0–0.1 to 0–276 bar)
Rugged construction using 316L SST, 316L SST, Inert, Alloy C-276, Alloy C-276, Silicone that guarantee long term of service in harsh environments.
Powered by advanced sensor technology
Simple integration possibilities
Accuracy:- ±0.10% of calibrated span. Includes combined effects of linearity, hysteresis, and repeatability.
Ambient Temperature:- Expressed as a total effect per 50 °F (28 °C). Total effect includes zero and span effects , +/- (0.15% URL + 0.15% of span) from -40 to 185 °F (-40 to 85 °C)
Stability: ±0.10% of upper range limit for 12 months.
Vibration Effect:- Less than ±0.1% of upper range limit when subjected to vibration of: peak to
peak constant displacement of 4 mm (5–15 Hz) and constant acceleration of
2 g (15–150 Hz) and 1 g (150–2000 Hz).
Power Supply Effect:- Less than 0.01% of calibrated span per volt.
Mounting Position Effect:- Zero shift of up to 1.2 inH2O (3 0.3 kPa), which can be calibrated out. No span effect.
RFI Effect:- Less than ±0.25% of upper range limit from 20–1000 MHz at 30 V/m with
leads in conduit. Less than ±0.25% of upper range limit at 10 V/m with
unshielded twisted pair (no conduit).
Temperature Limits Process Silicone fill sensor:- -40 to 250 °F (-40 to 121 °C).
Inert fill sensor:- -22 to 250 °F (-30 to 121 °C).
Ambient:- -40 to 185 °F (-40 to 85 °C), -4 to 175 °F (-20 to 80 °C) with LCD display
Storage:- -50 to 230 °F (-46 to 110 °C). -40 to 185 °F (-40 to 85 °C) with LCD display
0.075% high accuracy option
0.10% reference accuracy, including linearity, hysteresis, and repeatability
Absolute and gage pressure ranges from 0–1.5 psi to 0–4,000 psi (0–0.1 to 0–276 bar)
Rugged construction using 316L SST, 316L SST, Inert, Alloy C-276, Alloy C-276, Silicone that guarantee long term of service in harsh environments.
Powered by advanced sensor technology
Simple integration possibilities
Accuracy:- ±0.10% of calibrated span. Includes combined effects of linearity, hysteresis, and repeatability.
Ambient Temperature:- Expressed as a total effect per 50 °F (28 °C). Total effect includes zero and span effects , +/- (0.15% URL + 0.15% of span) from -40 to 185 °F (-40 to 85 °C)
Stability: ±0.10% of upper range limit for 12 months.
Vibration Effect:- Less than ±0.1% of upper range limit when subjected to vibration of: peak to
peak constant displacement of 4 mm (5–15 Hz) and constant acceleration of
2 g (15–150 Hz) and 1 g (150–2000 Hz).
Power Supply Effect:- Less than 0.01% of calibrated span per volt.
Mounting Position Effect:- Zero shift of up to 1.2 inH2O (3 0.3 kPa), which can be calibrated out. No span effect.
RFI Effect:- Less than ±0.25% of upper range limit from 20–1000 MHz at 30 V/m with
leads in conduit. Less than ±0.25% of upper range limit at 10 V/m with
unshielded twisted pair (no conduit).
Temperature Limits Process Silicone fill sensor:- -40 to 250 °F (-40 to 121 °C).
Inert fill sensor:- -22 to 250 °F (-30 to 121 °C).
Ambient:- -40 to 185 °F (-40 to 85 °C), -4 to 175 °F (-20 to 80 °C) with LCD display
Storage:- -50 to 230 °F (-46 to 110 °C). -40 to 185 °F (-40 to 85 °C) with LCD display