Accuracy:- ±0.10% of calibrated span. Includes combined effects of linearity, hysteresis, and repeatability.

Ambient Temperature:- Expressed as a total effect per 50 °F (28 °C). Total effect includes zero and span effects., +/- (0.15% URL + 0.15% of span) from -40 to 185 °F (-40 to 85 °C)

Stability:- ±0.10% of upper range limit for 12 months.

Vibration Effect:- Less than ±0.1% of upper range limit when subjected to vibration of: peak to
peak constant displacement of 4 mm (5–15 Hz) and constant acceleration of
2 g (15–150 Hz) and 1 g (150–2000 Hz).

Power Supply Effect:- Less than 0.01% of calibrated span per volt.

Mounting Position Effect:- Zero shift of up to 1.2 inH2O (3 0.3 kPa), which can be calibrated out. No span effect.

RFI Effect:- Less than ±0.25% of upper range limit from 20–1000 MHz at 30 V/m with
leads in conduit. Less than ±0.25% of upper range limit at 10 V/m with
unshielded twisted pair (no conduit).

4–20 mA HART (Output Code S) Output:- Two-wire 4–20 mA, user-selectable for linear or square root output. Digital process variable superimposed on 4–20 mA signal, available to any host
that conforms to the HART protocol.

Power Supply:- External power supply required. Standard transmitter operates on 10.5 to
42.4 Vdc with no load.

Temperature Limits Process Silicone fill sensor: –40 to 250 °F (–40 to 121 °C).
Inert fill sensor: –22 to 250 °F (–30 to 121 °C).

Ambient:- -40 to 185 °F (-40 to 85 °C) , -4 to 175 °F (-20 to 80 °C) with LCD display

Storage:- -50 to 230 °F (-46 to 110 °C). -40 to 185 °F (-40 to 85 °C) with LCD display

Electrical Connection:- 1/2–14 NPT, M20 x 1.5 or G 1/2 female (PF 1/2 female) conduit entry.

Electrical Connection:-1/2–14 NPT, M20 x 1.5 or G 1/2 female (PF 1/2 female) conduit entry.

Process Connection:- 1/2–14 NPT female, DIN 16288 G 1/2 male, RC 1/2 female (PT 1/2 female),
M20 x1.5 male.

Rosemount 2088 G4S22A1B4Q4 Cal. 0 To 4000Psi Pressure Transmitter

Accuracy:- ±0.10% of calibrated span. Includes combined effects of linearity, hysteresis, and repeatability.

Ambient Temperature:- Expressed as a total effect per 50 °F (28 °C). Total effect includes zero and span effects., +/- (0.15% URL + 0.15% of span) from -40 to 185 °F (-40 to 85 °C)

Stability:- ±0.10% of upper range limit for 12 months.

Vibration Effect:- Less than ±0.1% of upper range limit when subjected to vibration of: peak to
peak constant displacement of 4 mm (5–15 Hz) and constant acceleration of
2 g (15–150 Hz) and 1 g (150–2000 Hz).

Power Supply Effect:- Less than 0.01% of calibrated span per volt.

Mounting Position Effect:- Zero shift of up to 1.2 inH2O (3 0.3 kPa), which can be calibrated out. No span effect.

RFI Effect:- Less than ±0.25% of upper range limit from 20–1000 MHz at 30 V/m with
leads in conduit. Less than ±0.25% of upper range limit at 10 V/m with
unshielded twisted pair (no conduit).

4–20 mA HART (Output Code S) Output:- Two-wire 4–20 mA, user-selectable for linear or square root output. Digital process variable superimposed on 4–20 mA signal, available to any host
that conforms to the HART protocol.

Power Supply:- External power supply required. Standard transmitter operates on 10.5 to
42.4 Vdc with no load.

Temperature Limits Process Silicone fill sensor: –40 to 250 °F (–40 to 121 °C).
Inert fill sensor: –22 to 250 °F (–30 to 121 °C).

Ambient:- -40 to 185 °F (-40 to 85 °C) , -4 to 175 °F (-20 to 80 °C) with LCD display

Storage:- -50 to 230 °F (-46 to 110 °C). -40 to 185 °F (-40 to 85 °C) with LCD display

Electrical Connection:- 1/2–14 NPT, M20 x 1.5 or G 1/2 female (PF 1/2 female) conduit entry.

Electrical Connection:-1/2–14 NPT, M20 x 1.5 or G 1/2 female (PF 1/2 female) conduit entry.

Process Connection:- 1/2–14 NPT female, DIN 16288 G 1/2 male, RC 1/2 female (PT 1/2 female),