s

Phoenix Contact MCR-C-UI-UI-DCI 2810913

MCR 3-way signal conditioner, with configurable input/output, for the electrical isolation of analog signals, preconfigured.

The 3-way isolation means that the modules can be used universally, both on site or in the vicinity of the controller for signal conversion and electrical isolation, and along the transmission path to bridge high load resistance values.

Signals are converted by means of an inductive transmission method. In addition, a filter connected downstream of the transmitter reduces possible interference.

Alignment span :- ± 2 %

Limit Frequency (3 dB) :- 30 Hz

Maximum Power Dissipation for nominal Condition :- 900 mW

Test voltage input/output :- 1.5 kV AC (50 Hz, 60 s)

Step response (10-90%) :- 11 ms

Maximum temperature coefficient :- 0.0075 %/K

Supply voltage range :- 18 V DC…30 V DC

Max. current consumption :- < 30 mA (without load)

Voltage input signal :- 0 V ... 10 V (please indicate if different setting when ordering)

Max. voltage input signal :- 30 V

Max. current input signal :- 50 mA

Input resistance current input :- 50 Ω

Supply Voltage :- 24 V DC

Max. voltage output signal :- 15 V

Max. Current Output Signal :- 30 mA

Load/output load voltage output :- ≥ 10 kΩ

Load/output load current output :- ≤ 500 Ω

Stripping length :- 8 mm

Screw thread :- M3

Conductor cross section rigid :- 0.2 mm² ... 2.5 mm²

Conductor cross section AWG :- 24…14

Ambient temperature (operation) :- -20 °C ... 65 °C

Mounting type :- DIN Rail Mount

Phoenix Contact MCR-C-UI-UI-DCI 2810913

MCR 3-way signal conditioner, with configurable input/output, for the electrical isolation of analog signals, preconfigured.

The 3-way isolation means that the modules can be used universally, both on site or in the vicinity of the controller for signal conversion and electrical isolation, and along the transmission path to bridge high load resistance values.

Signals are converted by means of an inductive transmission method. In addition, a filter connected downstream of the transmitter reduces possible interference.

Alignment span :- ± 2 %

Limit Frequency (3 dB) :- 30 Hz

Maximum Power Dissipation for nominal Condition :- 900 mW

Test voltage input/output :- 1.5 kV AC (50 Hz, 60 s)

Step response (10-90%) :- 11 ms

Maximum temperature coefficient :- 0.0075 %/K

Supply voltage range :- 18 V DC…30 V DC

Max. current consumption :- < 30 mA (without load)

Voltage input signal :- 0 V ... 10 V (please indicate if different setting when ordering)

Max. voltage input signal :- 30 V

Max. current input signal :- 50 mA

Input resistance current input :- 50 Ω

Supply Voltage :- 24 V DC

Max. voltage output signal :- 15 V

Max. Current Output Signal :- 30 mA

Load/output load voltage output :- ≥ 10 kΩ

Load/output load current output :- ≤ 500 Ω

Stripping length :- 8 mm

Screw thread :- M3

Conductor cross section rigid :- 0.2 mm² ... 2.5 mm²

Conductor cross section AWG :- 24…14

Ambient temperature (operation) :- -20 °C ... 65 °C

Mounting type :- DIN Rail Mount