s

Phoenix Contact Interbus IB IL 24 PSDI 8-PAC order. No. 2985688 Module Id 163/17

Safety-related digital input module, IP20 protection, for the SafetyBridge, INTERBUS-Safety, and PROFIsafe system. The module has 4 safe digital inputs for two-channel assignment or 8 safe digital inputs for single-channel assignment.

Input name :-  Digital inputs

Transmission speed :- 500 kBit/s 2MBit/s

Input voltage :-  24 V DC (via clock outputs UT1 and UT2 or external supply)

Input voltage range "0" signal :- -3 V DC ... 5 V DC

 Input voltage range "1" signal :- 11 V DC ... 30 V DC

 Typical input current per channel :- 4.2 mA (at 24 V)

Supply voltage :- 24 V DC (via voltage jumper)

Supply voltage range :-  19.2 V DC ... 30 V DC

Current consumption :-  max. 180 mA (from the local bus)

Mounting type:-  DIN rail

Ambient temperature (operation):- -25 °C ... 55 °C

Ambient temperature (storage/transport) :-  -25 °C ... 70 °C

 Permissible humidity (operation) :-  10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.)

Air pressure (storage/transport) :-  66 kPa ... 108 kPa (up to 3500 m above mean sea level)

Communications power UL :- 7.5 V DC (see safety data)

Current consumption from UL :-  max. 180 mA

Main circuit supply UM :- 24 V DC

Supply voltage range UM :- 19.2 V DC ... 30 V DC (including ripple)

Phoenix Contact Interbus IB IL 24 PSDI 8-PAC order. No. 2985688 Module Id 163/17

Safety-related digital input module, IP20 protection, for the SafetyBridge, INTERBUS-Safety, and PROFIsafe system. The module has 4 safe digital inputs for two-channel assignment or 8 safe digital inputs for single-channel assignment.

Input name :-  Digital inputs

Transmission speed :- 500 kBit/s 2MBit/s

Input voltage :-  24 V DC (via clock outputs UT1 and UT2 or external supply)

Input voltage range "0" signal :- -3 V DC ... 5 V DC

 Input voltage range "1" signal :- 11 V DC ... 30 V DC

 Typical input current per channel :- 4.2 mA (at 24 V)

Supply voltage :- 24 V DC (via voltage jumper)

Supply voltage range :-  19.2 V DC ... 30 V DC

Current consumption :-  max. 180 mA (from the local bus)

Mounting type:-  DIN rail

Ambient temperature (operation):- -25 °C ... 55 °C

Ambient temperature (storage/transport) :-  -25 °C ... 70 °C

 Permissible humidity (operation) :-  10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.)

Air pressure (storage/transport) :-  66 kPa ... 108 kPa (up to 3500 m above mean sea level)

Communications power UL :- 7.5 V DC (see safety data)

Current consumption from UL :-  max. 180 mA

Main circuit supply UM :- 24 V DC

Supply voltage range UM :- 19.2 V DC ... 30 V DC (including ripple)