s

Emerson / Rosemount 1066-P-HT-06 Liquid Analitycal Transmitter

Rosemount 1066 Single Channel Transmitter is a loop powered device that can accept input from pH/ORP, conductivity (contacting and toroidal), and amperometric (dissolved oxygen, chlorine, and ozone) sensors.

 Faster installation using Quick Start programming

 Intrinsically Safe FM, CSA, and ATEX/IECEx Hazardous Location Approvals

 Visibility of process parameters by utilizing HART or Foundation Fieldbus digital communications

Transmits analytical  measurements: pH/ORP, Conductivity, Free Chlorine, Total Chlorine, Dissolved Oxygen, and Ozone.

 Large, easy to read, user customizable screen that displaysn analytical measurements, temperature, and diagnostics.

Effortlessly connect with PLCs and DCS' by choosing the HART or Profibus DP communication options.  Display measurements, configure alarms, and conduct maintenance with a simple to use local operator interface.

 Efficiently manage your devices using intuitive device dashboards on AMS/475 Communicators.

Display Resolution:- 128 x 96 pixel display resolution

ambient temperature and humidity:- -20 to 65°C (-4 to 149°F), RH 5 to 95% (non-condensing)

 storage temperature:-  -20 to 70°C (-4 to 158°F)

Power Minimum Voltage:- 12.7 Vdc

External Load Resistor for HART:- 250 Ohms

Terminal Wire Sizes Power:- 26-16 AWG

Sensor Inputs:- 26-16 AWG

Emerson / Rosemount 1066-P-HT-06 Liquid Analitycal Transmitter

Rosemount 1066 Single Channel Transmitter is a loop powered device that can accept input from pH/ORP, conductivity (contacting and toroidal), and amperometric (dissolved oxygen, chlorine, and ozone) sensors.

 Faster installation using Quick Start programming

 Intrinsically Safe FM, CSA, and ATEX/IECEx Hazardous Location Approvals

 Visibility of process parameters by utilizing HART or Foundation Fieldbus digital communications

Transmits analytical  measurements: pH/ORP, Conductivity, Free Chlorine, Total Chlorine, Dissolved Oxygen, and Ozone.

 Large, easy to read, user customizable screen that displaysn analytical measurements, temperature, and diagnostics.

Effortlessly connect with PLCs and DCS' by choosing the HART or Profibus DP communication options.  Display measurements, configure alarms, and conduct maintenance with a simple to use local operator interface.

 Efficiently manage your devices using intuitive device dashboards on AMS/475 Communicators.

Display Resolution:- 128 x 96 pixel display resolution

ambient temperature and humidity:- -20 to 65°C (-4 to 149°F), RH 5 to 95% (non-condensing)

 storage temperature:-  -20 to 70°C (-4 to 158°F)

Power Minimum Voltage:- 12.7 Vdc

External Load Resistor for HART:- 250 Ohms

Terminal Wire Sizes Power:- 26-16 AWG

Sensor Inputs:- 26-16 AWG