Bender RCM420 Linetraxx Residual Current Monitor RCM420-D-2

The AC and pulsed DC sensitive residual current monitor RCM420-D (Type A) from Bender is designed for fault and residual current monitoring in earthed power supply systems (TN and TT systems) where an alarm is to be activated in the event of a fault, but disconnection must be prevented. In addition, the device can be used to monitor single conductors, such as PE conductors, N-PE connections and PE-PAS connections.

AC and pulsed DC sensitive residual current monitor Type A according to IEC 62020

R.m.s. value measurement (AC)

Two separately adjustable response values

 Frequency range 42…2000 Hz

 Start-up delay, response delay and delay on release

 Restart function

 Digital measured value display via LC display

 Measured value memory for operating value

 CT connection monitoring

 LEDs: Power On, Alarm 1, Alarm 2

 Internal/external test/reset button

 Two separate alarm relays

Device self monitoring

 Sealable transparent cover

 Two-module enclosure (36 mm)

 RoHS compliant

 Push-wire terminal (two terminals per connection)

Adjustable pickup value from 10 mA to 10 A

Digital display showing measured ground-fault current in real-time

RESPONSE VALUE In = AC 10mA...10 A 42...20 Hz

SUPPLY VOLTAGE Us = AC/DC 70...300V

POWER CONSUMPTION :- 2,5 VA

RELAY CONTACTS :- AC250V 5A

Bender RCM420 Linetraxx Residual Current Monitor RCM420-D-2

The AC and pulsed DC sensitive residual current monitor RCM420-D (Type A) from Bender is designed for fault and residual current monitoring in earthed power supply systems (TN and TT systems) where an alarm is to be activated in the event of a fault, but disconnection must be prevented. In addition, the device can be used to monitor single conductors, such as PE conductors, N-PE connections and PE-PAS connections.

AC and pulsed DC sensitive residual current monitor Type A according to IEC 62020

R.m.s. value measurement (AC)

Two separately adjustable response values

 Frequency range 42…2000 Hz

 Start-up delay, response delay and delay on release

 Restart function

 Digital measured value display via LC display

 Measured value memory for operating value

 CT connection monitoring

 LEDs: Power On, Alarm 1, Alarm 2

 Internal/external test/reset button

 Two separate alarm relays

Device self monitoring

 Sealable transparent cover

 Two-module enclosure (36 mm)

 RoHS compliant

 Push-wire terminal (two terminals per connection)

Adjustable pickup value from 10 mA to 10 A

Digital display showing measured ground-fault current in real-time

RESPONSE VALUE In = AC 10mA...10 A 42...20 Hz

SUPPLY VOLTAGE Us = AC/DC 70...300V

POWER CONSUMPTION :- 2,5 VA

RELAY CONTACTS :- AC250V 5A