The AC and pulsed DC sensitive residual current monitor RCM420-D (Type A) from Bender is designed for fault and residual current monitoring in earthed power supply systems (TN and TT systems) where an alarm is to be activated in the event of a fault, but disconnection must be prevented. In addition, the device can be used to monitor single conductors, such as PE conductors, N-PE connections and PE-PAS connections.
AC and pulsed DC sensitive residual current monitor Type A according to IEC 62020
R.m.s. value measurement (AC)
Two separately adjustable response values
Frequency range 42…2000 Hz
Start-up delay, response delay and delay on release
Restart function
Digital measured value display via LC display
Measured value memory for operating value
CT connection monitoring
LEDs: Power On, Alarm 1, Alarm 2
Internal/external test/reset button
Two separate alarm relays
Device self monitoring
Sealable transparent cover
Two-module enclosure (36 mm)
RoHS compliant
Push-wire terminal (two terminals per connection)
Adjustable pickup value from 10 mA to 10 A
Digital display showing measured ground-fault current in real-time
RESPONSE VALUE In = AC 10mA...10 A 42...20 Hz
SUPPLY VOLTAGE Us = AC/DC 70...300V
POWER CONSUMPTION :- 2,5 VA
RELAY CONTACTS :- AC250V 5A
The AC and pulsed DC sensitive residual current monitor RCM420-D (Type A) from Bender is designed for fault and residual current monitoring in earthed power supply systems (TN and TT systems) where an alarm is to be activated in the event of a fault, but disconnection must be prevented. In addition, the device can be used to monitor single conductors, such as PE conductors, N-PE connections and PE-PAS connections.
AC and pulsed DC sensitive residual current monitor Type A according to IEC 62020
R.m.s. value measurement (AC)
Two separately adjustable response values
Frequency range 42…2000 Hz
Start-up delay, response delay and delay on release
Restart function
Digital measured value display via LC display
Measured value memory for operating value
CT connection monitoring
LEDs: Power On, Alarm 1, Alarm 2
Internal/external test/reset button
Two separate alarm relays
Device self monitoring
Sealable transparent cover
Two-module enclosure (36 mm)
RoHS compliant
Push-wire terminal (two terminals per connection)
Adjustable pickup value from 10 mA to 10 A
Digital display showing measured ground-fault current in real-time
RESPONSE VALUE In = AC 10mA...10 A 42...20 Hz
SUPPLY VOLTAGE Us = AC/DC 70...300V
POWER CONSUMPTION :- 2,5 VA
RELAY CONTACTS :- AC250V 5A