ABB REF615 Feeder Protection HBFFAEAGNBA1BNA1XE

·        Directional and non-directional overcurrent and earth-fault protection, voltage, frequency and power based protection and measurement functionality.

·        Extensive earth-fault protection portfolio with unique multi-frequency admittance-based protection for higher sensitivity and selectivity.

·         REF615 has been designed to be the main overcurrent and earth-fault protection for overhead lines and cable feeders, in either isolated neutral, resistance-earthed, compensated or effectively-earthed distribution networks, depending on the standard configuration.

·         Extensive range of protection and control functionality, either with sensors or conventional instrument transformers

·         Ready-made standard configurations for fast and easy setup with tailoring capabilities

·         Withdrawable plug-in unit design for swift installation and testing

·         Large graphical display for showing customizable SLDs, accessible either locally or through an easy-to-use web-browser-based HMI

·         Extensive life-cycle services

·         Ripple in the DC auxiliary voltage:-  Max 12% of the DC value (at frequency of 100 Hz)

·         Fuse type:-  T4 A/250 V

·         Rated frequency :- 50/60 Hz ± 5 Hz

·         Voltage input Rated voltage :- 100 V/ 110 V/ 115 V/ 120 V (Parametrization)

·         Operating range:-  ±20 % of the rated voltage

·         Rated voltage:-  24...250 V DC

·         Current drain:-  2...18 mA

·         Threshold voltage :- 18...176 V DC

·         Rated voltage 250 V AC/DC

·         Continuous carry :- 5 A

·         Minimum contact load :- 100 mA at 24 V AC/DC

·         Trip-circuit supervision Control voltage range :- 20...250 V AC/DC

·         Current drain through the supervision circuit :- ~1.5 m/A

·         Minimum voltage over the TCS contact :- 20 V AC/DC (15...20 V)

·         Normal service temperature range of the lens:- -40...+100 °C

·         Maximum service temperature range of the lens, max 1 h:-  +140°C

·         protection of flush-mounted relay Front side:-  IP 54

·         Top of the relay :-  IP 40

·         Rear side, connection terminals :- IP 20

ABB REF615 Feeder Protection HBFFAEAGNBA1BNA1XE

·        Directional and non-directional overcurrent and earth-fault protection, voltage, frequency and power based protection and measurement functionality.

·        Extensive earth-fault protection portfolio with unique multi-frequency admittance-based protection for higher sensitivity and selectivity.

·         REF615 has been designed to be the main overcurrent and earth-fault protection for overhead lines and cable feeders, in either isolated neutral, resistance-earthed, compensated or effectively-earthed distribution networks, depending on the standard configuration.

·         Extensive range of protection and control functionality, either with sensors or conventional instrument transformers

·         Ready-made standard configurations for fast and easy setup with tailoring capabilities

·         Withdrawable plug-in unit design for swift installation and testing

·         Large graphical display for showing customizable SLDs, accessible either locally or through an easy-to-use web-browser-based HMI

·         Extensive life-cycle services

·         Ripple in the DC auxiliary voltage:-  Max 12% of the DC value (at frequency of 100 Hz)

·         Fuse type:-  T4 A/250 V

·         Rated frequency :- 50/60 Hz ± 5 Hz

·         Voltage input Rated voltage :- 100 V/ 110 V/ 115 V/ 120 V (Parametrization)

·         Operating range:-  ±20 % of the rated voltage

·         Rated voltage:-  24...250 V DC

·         Current drain:-  2...18 mA

·         Threshold voltage :- 18...176 V DC

·         Rated voltage 250 V AC/DC

·         Continuous carry :- 5 A

·         Minimum contact load :- 100 mA at 24 V AC/DC

·         Trip-circuit supervision Control voltage range :- 20...250 V AC/DC

·         Current drain through the supervision circuit :- ~1.5 m/A

·         Minimum voltage over the TCS contact :- 20 V AC/DC (15...20 V)

·         Normal service temperature range of the lens:- -40...+100 °C

·         Maximum service temperature range of the lens, max 1 h:-  +140°C

·         protection of flush-mounted relay Front side:-  IP 54

·         Top of the relay :-  IP 40

·         Rear side, connection terminals :- IP 20