ABB N40E Contractor Relay 1SBH141001R8040

N... contactor relays are used for switching auxiliary circuits and control circuits - Poles: 4-pole contactor relays (mechanically linked contact elements available) - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.

N40E 220-230V 50Hz / 230-240V 60Hz Contactor Relay

Rated Operational Voltage:Main Circuit 690 volt

Rated Frequency (f):- Auxiliary Circuit 50 / 60 HzControl Circuit 50 / 60

Hz

Rated Control Circuit Voltage (Uc):- 50 Hz 220 ... 230 V60 Hz 230 ... 240 V

Coil Consumption:Holding at Max. Rated Control Circuit Voltage 50 Hz 8 2 volt - ampere, Holding at Max. Rated Control Circuit Voltage 60 Hz 8 2 volt - ampere, Pull-in at Max. Rated Control Circuit Voltage 50 Hz 70 volt - ampere, Pull-in at Max. Rated Control Circuit Volta

Max Mechanical Switching Frequency :- 6000 cycles per hour

Rated Control Circuit Voltage (Uc) :- 50 Hz 220-230V; 60 Hz 230-240V

Rated Frequency Limits :- 25 ... 400 hertz

Rated Frequency (f) :- Supply Circuit 50 60 hertz

Ambient Air Temperature :- Close to Contactor for Storage -60 ... +80 degree Celsius, Near Contactor for Operation in Free Air (Uc) -40 ... +70 degree Celsius, Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 degree Celsius

Rated Operational Current DC-13 (Ie) :- (125 V) 0.55 / 69 ampere, (24 V) 6 / 144 ampere, (250 V) 0.3 / 75 ampere, (48 V) 2.8 / 134 ampere, (72 V) 1 / 72 ampere

Rated Operational Current AC-15 (Ie) :- (220 / 240 V) 4 ampere, (24 / 127 V) 6 ampere, (380 / 440 V) 3 ampere, (500 V) 2 ampere, (690 V) 2 ampere

Operate Time :- Between Coil De-energization and NO Contact Opening 4 ... 11 millisecond, Between Coil Energization and NO Contact Closing 10 ... 26 millisecond

ABB N40E Contractor Relay 1SBH141001R8040

N... contactor relays are used for switching auxiliary circuits and control circuits - Poles: 4-pole contactor relays (mechanically linked contact elements available) - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.

N40E 220-230V 50Hz / 230-240V 60Hz Contactor Relay

Rated Operational Voltage:Main Circuit 690 volt

Rated Frequency (f):- Auxiliary Circuit 50 / 60 HzControl Circuit 50 / 60

Hz

Rated Control Circuit Voltage (Uc):- 50 Hz 220 ... 230 V60 Hz 230 ... 240 V

Coil Consumption:Holding at Max. Rated Control Circuit Voltage 50 Hz 8 2 volt - ampere, Holding at Max. Rated Control Circuit Voltage 60 Hz 8 2 volt - ampere, Pull-in at Max. Rated Control Circuit Voltage 50 Hz 70 volt - ampere, Pull-in at Max. Rated Control Circuit Volta

Max Mechanical Switching Frequency :- 6000 cycles per hour

Rated Control Circuit Voltage (Uc) :- 50 Hz 220-230V; 60 Hz 230-240V

Rated Frequency Limits :- 25 ... 400 hertz

Rated Frequency (f) :- Supply Circuit 50 60 hertz

Ambient Air Temperature :- Close to Contactor for Storage -60 ... +80 degree Celsius, Near Contactor for Operation in Free Air (Uc) -40 ... +70 degree Celsius, Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 degree Celsius

Rated Operational Current DC-13 (Ie) :- (125 V) 0.55 / 69 ampere, (24 V) 6 / 144 ampere, (250 V) 0.3 / 75 ampere, (48 V) 2.8 / 134 ampere, (72 V) 1 / 72 ampere

Rated Operational Current AC-15 (Ie) :- (220 / 240 V) 4 ampere, (24 / 127 V) 6 ampere, (380 / 440 V) 3 ampere, (500 V) 2 ampere, (690 V) 2 ampere

Operate Time :- Between Coil De-energization and NO Contact Opening 4 ... 11 millisecond, Between Coil Energization and NO Contact Closing 10 ... 26 millisecond