ABB DI810 3BSE008508R1 PR:G Wh base TU810V1 3BSE013230R1 PR: G

·       ABB DI810 3BSE008508R1:-

·        Isolated in two groups of 8 channels.
Use Module Termination Unit TU810, TU812, TU814, TU818, TU830, TU833, TU838, TU850.

·        This Digital Input Module features 16 digital inputs and the input voltage range is 18 to 30 Vdc.

·        The inputs are divided into two isolated groups with eight channels and one voltage supervision input in each group.

·         Every input channel consists of current limiting components, EMC protection, input state indication LEDs and an optical isolation barrier.

·        The process voltage supervision input give channel error signals if the voltage disappears with the error signal can be read via the ModuleBus

·        Number of Input Channels:- 16

·        I/O Voltage, DC:- 24 V

·        Technical Information:- DI810 Digital Input 24V d.c. 2x8 ch.

·        DI810 Digital Input

·        Rated isolation :- 50 V

·       TU810V1 3BSE013230R1:-

·        Compact Module Termination Unit 2x8 signal terminals.

·        TU810V1 Compact Module Termination Unit

·        MTU, 50V. 2x8 signal terminals, rated isol. 50V.

·        Voltage :- 50V

·        Channels :-  16

·        Mounting detail Horizontal :-  55 ºC (131 °F) , Vertical 40 ºC (104 °F)

·        Process connections :- 2 x 2 Process power, 5 x 2 Process power (0 V)

·        The TU810/TU810V1 is a 16 channel 50 V compact module termination unit (MTU) for the S800 I/O.

·        The MTU is a passive unit used for connection of the field wiring to the I/O modules. It also contains a part of the ModuleBus

·        Compact installation of I/O modules using one-wire connections.

·        Up to 16 channels of field signals and process power connections.

·        Connections to ModuleBus and I/O modules.

·        Mechanical keying prevents insertion of the wrong I/O module.

·        Latching device to DIN rail for grounding.

·        DIN rail mounting.

·        Maximum current per I/O channel :- 2A

·        Maximum current process connection :- 5A

·        Acceptable wire sizes Solid:-  0.2 -4mm² Stranded: 0.2 -2.5 mm², 24-12 AWG

·        Dielectric testvoltage :- 500 V a.c.

·        Temperature, Operating :-  0 to +55 °C (+32 to +131 °F), approvals are issued for +5 to +55 °C

·        Temperature, Storage :- -40 to + 70 °C (-40 to +158 °F)

·        Relative humidity :- 5 to 95 %, non-condensing

·         Max ambient temperature:-  55 °C (131 °F), forvertical mounting 40 °C (104°F)

·        Protection class:-  IP20 according to IEC 60529

ABB DI810 3BSE008508R1 PR:G Wh base TU810V1 3BSE013230R1 PR: G

·       ABB DI810 3BSE008508R1:-

·        Isolated in two groups of 8 channels.
Use Module Termination Unit TU810, TU812, TU814, TU818, TU830, TU833, TU838, TU850.

·        This Digital Input Module features 16 digital inputs and the input voltage range is 18 to 30 Vdc.

·        The inputs are divided into two isolated groups with eight channels and one voltage supervision input in each group.

·         Every input channel consists of current limiting components, EMC protection, input state indication LEDs and an optical isolation barrier.

·        The process voltage supervision input give channel error signals if the voltage disappears with the error signal can be read via the ModuleBus

·        Number of Input Channels:- 16

·        I/O Voltage, DC:- 24 V

·        Technical Information:- DI810 Digital Input 24V d.c. 2x8 ch.

·        DI810 Digital Input

·        Rated isolation :- 50 V

·       TU810V1 3BSE013230R1:-

·        Compact Module Termination Unit 2x8 signal terminals.

·        TU810V1 Compact Module Termination Unit

·        MTU, 50V. 2x8 signal terminals, rated isol. 50V.

·        Voltage :- 50V

·        Channels :-  16

·        Mounting detail Horizontal :-  55 ºC (131 °F) , Vertical 40 ºC (104 °F)

·        Process connections :- 2 x 2 Process power, 5 x 2 Process power (0 V)

·        The TU810/TU810V1 is a 16 channel 50 V compact module termination unit (MTU) for the S800 I/O.

·        The MTU is a passive unit used for connection of the field wiring to the I/O modules. It also contains a part of the ModuleBus

·        Compact installation of I/O modules using one-wire connections.

·        Up to 16 channels of field signals and process power connections.

·        Connections to ModuleBus and I/O modules.

·        Mechanical keying prevents insertion of the wrong I/O module.

·        Latching device to DIN rail for grounding.

·        DIN rail mounting.

·        Maximum current per I/O channel :- 2A

·        Maximum current process connection :- 5A

·        Acceptable wire sizes Solid:-  0.2 -4mm² Stranded: 0.2 -2.5 mm², 24-12 AWG

·        Dielectric testvoltage :- 500 V a.c.

·        Temperature, Operating :-  0 to +55 °C (+32 to +131 °F), approvals are issued for +5 to +55 °C

·        Temperature, Storage :- -40 to + 70 °C (-40 to +158 °F)

·        Relative humidity :- 5 to 95 %, non-condensing

·         Max ambient temperature:-  55 °C (131 °F), forvertical mounting 40 °C (104°F)

·        Protection class:-  IP20 according to IEC 60529