The CT-AHS.22S is a single-function electronic time relay from the CT-S timer range.
It provides an OFF-delay (delay on break) function with 10 time ranges from 0.05 s to 300 h.
This time relay operates with a rated control supply voltage of 24 - 48 V DC / 24 - 240 V AC and has a 2 c/o (SPDT) output with contacts rated at 250 V / 4 A.
A control input works with volt-free (floating) triggering.
A sealable transparent cover for protection against unauthorized changes is available as accessory.
The device offers screw connection technology with double-chamber cage connection terminals.
CT-AHS.22S Time relay, OFF-delay 2c/o, 24-48VDC, 24-240VAC
Time Range:- 0.05 s ... 300 h
Rated Control Supply Voltage (Us):- 24 ... 240 V AC, 24 ... 48 V DC
Rated Operational Voltage:- Auxiliary Circuit 250 V
Rated Frequency (f):- 50 / 60 Hz DC
Output:-2 c/o (SPDT) contacts
Rated Impulse Withstand Voltage (Uimp):- Input Circuit 4 kV, Output Circuit 1 / Output Circuit 2 4 kV
Rated Insulation Voltage (Ui):- Input Circuit / Output Circuit 500 V, Output Circuit 1 / Output Circuit 2 300 V
Electrical Durability:- AC-12 100000 cycle
Tightening Torque:- 0.6 ... 0.8 N·m
Maximum Operating Voltage UL/CSA:- Output Circuit 300 V AC
Ambient Air Temperature Operation:- -25 ... +60 °C
Ambient Air Temperature Storage:- -40 ... +85 °C
The CT-AHS.22S is a single-function electronic time relay from the CT-S timer range.
It provides an OFF-delay (delay on break) function with 10 time ranges from 0.05 s to 300 h.
This time relay operates with a rated control supply voltage of 24 - 48 V DC / 24 - 240 V AC and has a 2 c/o (SPDT) output with contacts rated at 250 V / 4 A.
A control input works with volt-free (floating) triggering.
A sealable transparent cover for protection against unauthorized changes is available as accessory.
The device offers screw connection technology with double-chamber cage connection terminals.
CT-AHS.22S Time relay, OFF-delay 2c/o, 24-48VDC, 24-240VAC
Time Range:- 0.05 s ... 300 h
Rated Control Supply Voltage (Us):- 24 ... 240 V AC, 24 ... 48 V DC
Rated Operational Voltage:- Auxiliary Circuit 250 V
Rated Frequency (f):- 50 / 60 Hz DC
Output:-2 c/o (SPDT) contacts
Rated Impulse Withstand Voltage (Uimp):- Input Circuit 4 kV, Output Circuit 1 / Output Circuit 2 4 kV
Rated Insulation Voltage (Ui):- Input Circuit / Output Circuit 500 V, Output Circuit 1 / Output Circuit 2 300 V
Electrical Durability:- AC-12 100000 cycle
Tightening Torque:- 0.6 ... 0.8 N·m
Maximum Operating Voltage UL/CSA:- Output Circuit 300 V AC
Ambient Air Temperature Operation:- -25 ... +60 °C
Ambient Air Temperature Storage:- -40 ... +85 °C