s
Supplier Of Industrial and Marine Equipments
· ABB CI840A 3BSE041882R1:-
· S800 I/O is a comprehensive, distributed and modular process I/O system that communicates with parent controllers and PLCs over industry-standard field buses.
· The CI840 Fieldbus Communication Interface (FCI) module is a configurable communication interface that performs operations such as signal processing, gathering of various supervision information, OSP handling, Hot Configuration In Run, HART pass-through and configuration of I/O modules.
· CI840 is designed for redundant applications.
· The FCI connects to the controller by way of the PROFIBUS-DPV1 fieldbus.
· Module termination units to use, TU846 with redundant I/O and TU847 with non-redundant I/O.
· For redundant communication interface two CI840A, and one TU847 or one TU846 must be ordered.
· Product Type:- Communication_Module
· 24 V consumption typ.:- 190 mA
· Temperature, Operating :- 0 to +55 °C (+32 to +131 °F), approvals are issued for +5 to +55 °C
· Temperature, Storage :- -40 to +70 °C (-40 to +158 °F)
· Relative humidity :- 5 to 95 %, non-condensing
· Max ambient temperature :- 55 °C (131 °F), for vertical mounting 40 °C (104 °F)
· Protection class :- IP20
· ABB 3BSE022462R1 :-
· The TU847 is a module termination unit (MTU) for redundant configuration of the field communication interface CI840/CI840A.
· The MTU is a passive unit having connections for power supply, electrical ModuleBus, two CI840/CI840A and two rotary switches for station address (0 to 99) settings.
· A ModuleBus Optical Port TB842 can be connected to TU847 via TB806.
· Four mechanical keys, two for each position, are used to configured the MTU for the right types of modules.
· Each key has six positions, which gives a total number of 36 different configurations.
· TU846/TU847 needs space to the left in order to be removed.
· Cannot be replaced with power applied. TU847 is also available in a G3 compliant version (TU847Z).
· Type :- Redundant CI840/CI840A, Single I/O
· Power input :- 24 V d.c. (19.2 - 30 V)
· Mounting :- Vertical or Horizontal
· ModuleBus current distribution :- Maximum 5 V 1.5 A Maximum 24 V 1.5 A
· Acceptable wire sizes :- 0.25 - 2.5mm², 24 - 14 AWG Recommended torque: 0.5 - 0.6 Nm Stripping length: 6-7.5 mm, 0.24-0.30 in
· Rated insulation voltage :- 50 V
· Dialectic test voltage :- 500 V ac
· Temperature, Operating:- 0 to +55 °C (+32 to +131 °F), approvals are issued for +5 to +55 °C
· Temperature, Storage:- -40 to +70 °C (-40 to +158° F)
· Relative humidity :- 5 to 95 %, non-condensing
· Max ambient temperature :- 55 °C (131 °F), for vertical mounting 40 °C (104 °F)
· Ingress protection :- IP20
· ABB CI840A 3BSE041882R1:-
· S800 I/O is a comprehensive, distributed and modular process I/O system that communicates with parent controllers and PLCs over industry-standard field buses.
· The CI840 Fieldbus Communication Interface (FCI) module is a configurable communication interface that performs operations such as signal processing, gathering of various supervision information, OSP handling, Hot Configuration In Run, HART pass-through and configuration of I/O modules.
· CI840 is designed for redundant applications.
· The FCI connects to the controller by way of the PROFIBUS-DPV1 fieldbus.
· Module termination units to use, TU846 with redundant I/O and TU847 with non-redundant I/O.
· For redundant communication interface two CI840A, and one TU847 or one TU846 must be ordered.
· Product Type:- Communication_Module
· 24 V consumption typ.:- 190 mA
· Temperature, Operating :- 0 to +55 °C (+32 to +131 °F), approvals are issued for +5 to +55 °C
· Temperature, Storage :- -40 to +70 °C (-40 to +158 °F)
· Relative humidity :- 5 to 95 %, non-condensing
· Max ambient temperature :- 55 °C (131 °F), for vertical mounting 40 °C (104 °F)
· Protection class :- IP20
· ABB 3BSE022462R1 :-
· The TU847 is a module termination unit (MTU) for redundant configuration of the field communication interface CI840/CI840A.
· The MTU is a passive unit having connections for power supply, electrical ModuleBus, two CI840/CI840A and two rotary switches for station address (0 to 99) settings.
· A ModuleBus Optical Port TB842 can be connected to TU847 via TB806.
· Four mechanical keys, two for each position, are used to configured the MTU for the right types of modules.
· Each key has six positions, which gives a total number of 36 different configurations.
· TU846/TU847 needs space to the left in order to be removed.
· Cannot be replaced with power applied. TU847 is also available in a G3 compliant version (TU847Z).
· Type :- Redundant CI840/CI840A, Single I/O
· Power input :- 24 V d.c. (19.2 - 30 V)
· Mounting :- Vertical or Horizontal
· ModuleBus current distribution :- Maximum 5 V 1.5 A Maximum 24 V 1.5 A
· Acceptable wire sizes :- 0.25 - 2.5mm², 24 - 14 AWG Recommended torque: 0.5 - 0.6 Nm Stripping length: 6-7.5 mm, 0.24-0.30 in
· Rated insulation voltage :- 50 V
· Dialectic test voltage :- 500 V ac
· Temperature, Operating:- 0 to +55 °C (+32 to +131 °F), approvals are issued for +5 to +55 °C
· Temperature, Storage:- -40 to +70 °C (-40 to +158° F)
· Relative humidity :- 5 to 95 %, non-condensing
· Max ambient temperature :- 55 °C (131 °F), for vertical mounting 40 °C (104 °F)
· Ingress protection :- IP20