ABB AO820 3BSE008546R1 PR:J With Base 3BSE013234R1 PR:H

·       ABB AO820 3BSE008546R1:-

·        +-20mA, 0(4)...20mA, +-10V, 12bit+sign. Individually galvanic isolated channels.

·        RL max 500 Ohms. Use Module Termination Unit TU810, TU812, TU814, TU830, TU833.

·        The AO820 Analog Output Module has 4 bipolar analog output channels.

·        The choice of current or voltage output is configurable for each channel.

·        There are separate sets of terminals for voltage and current outputs, and it is up to the user to wire outputs properly.

·        The only differences between current or voltage channel configuration is in software settings.

·        Signal specification :- -20 mA...+20 mA, 0...20 mA, 4...20 mA, -10 V...+10 V, 0...10 V, 2...10 V

·        Resolution :- 12 bits including sign

·        Isolation :- Individually isolated - channel-to-channel and channel to circuit common

·        Under/over range :- ±15%

·        Output load :- ≤ 550 Ω≥ 5 kΩ (voltage output)

·        Temperature drift :- Max 90 ppm/°C

·        Rise Time :- < 0.7 ms

·        Update cycle time :- ≤ 1.5 ms

·        Maximum field cable length :- 600 meters (656 yards)

·        Rated insulation voltage :- 50 V

·        Dielectric test voltage :- 500 V a.c.

·        Power dissipation :- Typ. 6 W

·        Current consumption +5 V Modulebus :- Max 100 mA

·        Current consumption +24 V Modulebus :- Max 260 mA

·        Temperature, Operating :- 0 to +55 °C (+32 to +131 °F), approvals are issued for +5 to +55 °C

·        Temperature, Storage :- -40 to +70 °C (-40 to +158 °F)

·        Relative humidity :- 5 to 95 %, non-condensing

·        Max ambient temperature :- 55 °C (131 °F), for vertical mounting in compact MTU 40 °C (104 °F)

·        Protection class :- IP20

·       3BSE013234R1:-

·        Extended Module Termination Unit 2x16 signal terminals.

·        Mounting detail:- 55 ºC (131 °F)

·        Channel :- 16

·        Voltage :- 50 V

ABB AO820 3BSE008546R1 PR:J With Base 3BSE013234R1 PR:H

·       ABB AO820 3BSE008546R1:-

·        +-20mA, 0(4)...20mA, +-10V, 12bit+sign. Individually galvanic isolated channels.

·        RL max 500 Ohms. Use Module Termination Unit TU810, TU812, TU814, TU830, TU833.

·        The AO820 Analog Output Module has 4 bipolar analog output channels.

·        The choice of current or voltage output is configurable for each channel.

·        There are separate sets of terminals for voltage and current outputs, and it is up to the user to wire outputs properly.

·        The only differences between current or voltage channel configuration is in software settings.

·        Signal specification :- -20 mA...+20 mA, 0...20 mA, 4...20 mA, -10 V...+10 V, 0...10 V, 2...10 V

·        Resolution :- 12 bits including sign

·        Isolation :- Individually isolated - channel-to-channel and channel to circuit common

·        Under/over range :- ±15%

·        Output load :- ≤ 550 Ω≥ 5 kΩ (voltage output)

·        Temperature drift :- Max 90 ppm/°C

·        Rise Time :- < 0.7 ms

·        Update cycle time :- ≤ 1.5 ms

·        Maximum field cable length :- 600 meters (656 yards)

·        Rated insulation voltage :- 50 V

·        Dielectric test voltage :- 500 V a.c.

·        Power dissipation :- Typ. 6 W

·        Current consumption +5 V Modulebus :- Max 100 mA

·        Current consumption +24 V Modulebus :- Max 260 mA

·        Temperature, Operating :- 0 to +55 °C (+32 to +131 °F), approvals are issued for +5 to +55 °C

·        Temperature, Storage :- -40 to +70 °C (-40 to +158 °F)

·        Relative humidity :- 5 to 95 %, non-condensing

·        Max ambient temperature :- 55 °C (131 °F), for vertical mounting in compact MTU 40 °C (104 °F)

·        Protection class :- IP20

·       3BSE013234R1:-

·        Extended Module Termination Unit 2x16 signal terminals.

·        Mounting detail:- 55 ºC (131 °F)

·        Channel :- 16

·        Voltage :- 50 V