· ABB AO820 3BSE008546R1:-
· +-20mA, 0(4)...20mA, +-10V, 12bit+sign. Individually galvanic isolated channels.
· RL max 500 Ohms. Use Module Termination Unit TU810, TU812, TU814, TU830, TU833.
· The AO820 Analog Output Module has 4 bipolar analog output channels.
· The choice of current or voltage output is configurable for each channel.
· There are separate sets of terminals for voltage and current outputs, and it is up to the user to wire outputs properly.
· The only differences between current or voltage channel configuration is in software settings.
· Signal specification :- -20 mA...+20 mA, 0...20 mA, 4...20 mA, -10 V...+10 V, 0...10 V, 2...10 V
· Resolution :- 12 bits including sign
· Isolation :- Individually isolated - channel-to-channel and channel to circuit common
· Under/over range :- ±15%
· Output load :- ≤ 550 Ω, ≥ 5 kΩ (voltage output)
· Temperature drift :- Max 90 ppm/°C
· Rise Time :- < 0.7 ms
· Update cycle time :- ≤ 1.5 ms
· Maximum field cable length :- 600 meters (656 yards)
· Rated insulation voltage :- 50 V
· Dielectric test voltage :- 500 V a.c.
· Power dissipation :- Typ. 6 W
· Current consumption +5 V Modulebus :- Max 100 mA
· Current consumption +24 V Modulebus :- Max 260 mA
· Temperature, Operating :- 0 to +55 °C (+32 to +131 °F), approvals are issued for +5 to +55 °C
· Temperature, Storage :- -40 to +70 °C (-40 to +158 °F)
· Relative humidity :- 5 to 95 %, non-condensing
· Max ambient temperature :- 55 °C (131 °F), for vertical mounting in compact MTU 40 °C (104 °F)
· Protection class :- IP20
· 3BSE013234R1:-
· Extended Module Termination Unit 2x16 signal terminals.
· Mounting detail:- 55 ºC (131 °F)
· Channel :- 16
· Voltage :- 50 V
· ABB AO820 3BSE008546R1:-
· +-20mA, 0(4)...20mA, +-10V, 12bit+sign. Individually galvanic isolated channels.
· RL max 500 Ohms. Use Module Termination Unit TU810, TU812, TU814, TU830, TU833.
· The AO820 Analog Output Module has 4 bipolar analog output channels.
· The choice of current or voltage output is configurable for each channel.
· There are separate sets of terminals for voltage and current outputs, and it is up to the user to wire outputs properly.
· The only differences between current or voltage channel configuration is in software settings.
· Signal specification :- -20 mA...+20 mA, 0...20 mA, 4...20 mA, -10 V...+10 V, 0...10 V, 2...10 V
· Resolution :- 12 bits including sign
· Isolation :- Individually isolated - channel-to-channel and channel to circuit common
· Under/over range :- ±15%
· Output load :- ≤ 550 Ω, ≥ 5 kΩ (voltage output)
· Temperature drift :- Max 90 ppm/°C
· Rise Time :- < 0.7 ms
· Update cycle time :- ≤ 1.5 ms
· Maximum field cable length :- 600 meters (656 yards)
· Rated insulation voltage :- 50 V
· Dielectric test voltage :- 500 V a.c.
· Power dissipation :- Typ. 6 W
· Current consumption +5 V Modulebus :- Max 100 mA
· Current consumption +24 V Modulebus :- Max 260 mA
· Temperature, Operating :- 0 to +55 °C (+32 to +131 °F), approvals are issued for +5 to +55 °C
· Temperature, Storage :- -40 to +70 °C (-40 to +158 °F)
· Relative humidity :- 5 to 95 %, non-condensing
· Max ambient temperature :- 55 °C (131 °F), for vertical mounting in compact MTU 40 °C (104 °F)
· Protection class :- IP20
· 3BSE013234R1:-
· Extended Module Termination Unit 2x16 signal terminals.
· Mounting detail:- 55 ºC (131 °F)
· Channel :- 16
· Voltage :- 50 V